Description
Schneider Compact Circuit Breaker Product Features Series: Compact Product name: Compact NSX Product series: ComPact NSX100…250 Product group: NSX250F Product or component type: Circuit breaker Device application: Distribution Number of poles: 3P Protected pole description : 3t [In] nominal current : 200 A at 40 ?C [Ue] nominal operating voltage : 690 V AC 50/60 Hz Mains type : AC Mains frequency : 50/60 Hz Suitability for insulation : Yes conforming to EN/IEC 60947 -2 Usage category: Category A [Icu] rated ultimate short-circuit breaking capacity: 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947- 2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50 /60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508 Performance level : F 36 kA 415 V AC Trip unit name : TM-D Trip unit technology : Thermal Magnetic Trip unit protection functions: LI Control type: Through Circuit breaker mounting mode: Fixed Supplementary Features [Ui] nominal insulation voltage: 800 V AC 50/60 Hz [Uimp] nominal impulse withstand voltage: 8 kV [Ics] rated service short-circuit breaking capacity : 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Mechanical durability: 20000 cycles Electrical durability: 5000 cycles at 690 V In 10000 cycles at 690 V In/2 10000 cycles at 440 V In 20000 cycles at 440 V In/2 Mounting support: Back plate Upper connection: Front Down connection: Front Connection distance: 35 mm Protection type: Overload protection (thermal) Short circuit protection (magnetic) Trip unit rating: 200 A at 40 ?C Long-time pick-up adjustment type Ir (thermal protection) : Adjustable [Ir] long-time protection pick-up adjustment range : 0.7…1 x In Long-time protection delay adjustment type tr : Fixed [tr] long-time protection delay adjustment range : 120?400 s at 1.5 x In 15 s at 6 x Ir Short-time protection pick-up adjustment type Isd : Adjustable [Isd] Short-time protection pick-up adjustment range : 5…10 x In Short-time protection delay adjustment type tsd : Fixed Earth leakage protection : None Number of slots for electrical auxiliaries : 5 slot(s) Width (W) : 105 mm Height (H) : 161 mm Depth (D) : 86 mm Product weight: 2.4 kg Environmental Conditions Standards: EN/IEC 60947 Product certifications: Marine CCC EAC Overvoltage category: Class II Electric shock protection class: Class II Pollution degree: 3 Conforming to IEC 60664-1 IP degree of protection:IP40 conforming to IEC 60529 IK protection degree: IK07 conforming to IEC 62262 Nominal operating ambient temperature: -25?70 ?C Storage ambient conditions: -50?85 ?C Relative humidity: 0?95 % Operating altitude: 0…2000 m without depreciation 2000 m…5000 m with depreciation